The hydraulic pump mainly provides power for the hydraulic system to complete the working process of cab lifting and cab falling back, while the electric plunger assembly inside the traditional hydraulic pump is generally connected with a conical spring
Cabin Cab Lift Hydraulic Pump,Cab Lift Pump,Cabin Cab Lift Electric Pump,Hydraulic Cab Lift Pump Jilin Province Xuan Yi Trading Co.,Ltd. , https://www.xytruckparts.com
XBDL vertical 1stage & 1priming pumps system, used to transfer clear water and similar liquids with similar physical & chemical properties, without solid particles, applied and suitable in pressure boosted water supply in fire fight systems, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.
   XBD-L fire fight pumps system's performance and technical parameters comply with GB6245-1998 "Performance requirements and test methods for fire pumps", and obtains certificates from "China National Fire Fight Equipment Quality Supervision & Testing Center".
   Computer design and optimized processing, strong technical power, rich manufacture experiences and perfect test methods ensure stable and reliable quality.
Characteristics:
1. Compact structure, small, nice, vertical installation, less area for installation needed, gravity on feet, stable running and long life.
2. Stable running, little noise, highly concentric components.
3. Advanced hydraulic model, high efficiency and performance.
4. The superior mechanical shaft seal, highly endurable against friction, no leak, long life.
5. The pump inlet and outlet are on a same horizontal line, same sizes, easy to install and uninstall.
6. Easy to maintain, pipes uninstall is not needed, you only need take off pump cap nuts, then take out motor and transmission elements, before maintaining.
Technical parameters:
flow:Â 5-100L/S;
pressure:Â 0.10-1.25Mpa;
power:Â 1.1-250KW;
rotation speed: 980-2900r/min;
diameter: φ50-φ300;
temperature range:≤80ºC.
Model number
Flow Q
(L/s)Outlet pressure
(MPa)Rotation speed n
(r/min)Power P
(Kw)Efficiency η
(%)
XBD3.0/5-50(65)
5
0.30
2900
4
63
XBD3.2/5-50(65)
0.32
XBD3.4/5-50(65)
0.34
XBD4.6/5-50(65)
5
0.46
2900
7.5
58
XBD4.8/5-50(65)
0.48
XBD5.0/5-50(65)
0.50
XBD7.6/5-50(65)
5
0.76
2900
15
50
XBD7.8/5-50(65)
0.78
XBD8.0/5-50(65)
0.80
XBD11/5-50(65)
5
1.10
2900
30
40
XBD12/5-50(65)
1.20
XBD12.5/5-50(65)
1.25
XBD3.0/10-65(80)
10
0.30
2900
7.5
71
XBD3.2/10-65(80)
0.32
XBD3.4/10-65(80)
0.34
XBD4.6/10-65(80)
10
0.46
2900
15
67
XBD4.8/10-65(80)
0.48
XBD5.0/10-65(80)
0.50
XBD7.6/10-65(80)
10
0.76
2900
22
59
XBD7.8/10-65(80)
0.78
XBD8.0/10-65(80)
0.80
XBD11/10-65(80)
10
1.10
2900
37
54
XBD12/10-65(80)
1.20
XBD12.5/10-65(80)
1.25
XBD3.0/25-80(100)
25
0.30
2900
15
76
XBD3.2/25-80(100)
0.32
XBD3.4/25-80(100)
0.34
XBD4.6/25-80(100)
25
0.46
2900
22
74
XBD4.8/25-80(100)
0.48
XBD5.0/25-80(100)
0.50
XBD7.6/25-80(100)
25
0.76
2900
37
69
XBD7.8/25-80(100)
0.78
XBD8.0/25-80(100)
0.80
XBD11/25-80(100)
25
1.10
2900
75
69
XBD12/25-80(100)
1.20
XBD12.5/25-80(100)
1.25
XBD13/25-80(100)
25
1.30
2900
90
57
XBD14/25-80(100)
1.40
XBD15/25-80(100)
1.50
XBD3.0/45-100(125)
45
0.30
2900
22
73
XBD3.2/45-100(125)
0.32
XBD3.4/45-100(125)
0.34
XBD4.6/45-100(125)
45
0.46
2900
37
77
XBD4.8/45-100(125)
0.48
XBD5.0/45-100(125)
0.50
XBD7.6/45-100(125)
45
0.76
2900
55
80
XBD7.8/45-100(125)
0.78
XBD8.0/45-100(125)
0.80
XBD11/45-100(125)
45
1.10
2900
90
70
XBD12/45-100(125)
1.20
XBD12.5/45-100(125)
1.25
XBD2.8/55-150(200)
55
0.28
1450
30
78
XBD3.0/55-150(200)
0.30
XBD3.2/55-150(200)
0.32
XBD4.6/55-150(200)
55
0.46
1450
45
75
XBD4.8/55-150(200)
0.48
XBD5.0/55-150(200)
0.50
XBD7.6/55-150
55
0.76
2900
75
76
XBD7.8/55-150
0.78
XBD8.0/55-150
0.80
XBD11/55-150
55
1.10
2900
110
73
XBD12/55-150
1.20
XBD12.5/55-150
1.25
XBD13/55-150
45
1.30
2900
110
80
XBD14/55-150
1.40
XBD15/55-150
1.50
XBD4.6/100-200
100
0.46
1450
75
81
XBD4.8/100-200
0.48
XBD5.0/100-200
0.50
XBD3.0/150-250
150
0.30
1450
75
80
XBD3.2/150-250
0.32
XBD3.4/150-250
0.34
XBD4.6/140-250
140
0.46
1450
90
72
XBD4.8/140-250
0.48
XBD5.0/140-250
0.50
XBD2.4/200-300
200
0.24
970
75
81
XBD2.6/200-300
0.26
XBD2.8/200-300
0.28
XBD2.8/200-300(350)
200
0.28
1450
90
84
XBD3.0/200-300(350)
0.30
XBD3.2/200-300(350)
0.32
XBD4.0/200-300
200
0.40
970
132
84
XBD4.2/200-300
0.42
XBD4.4/200-300
0.44
XBD4.6/160-300
160
0.46
1450
110
78
XBD4.8/160-300
0.48
XBD5.0/160-300
0.50
XBD4.6/200-350
200
0.46
1450
160
83
XBD4.8/200-350
0.48
XBD5.0/200-350
0.50
XBD2.8/300-400
300
0.28
1450
132
76
XBD3.0/300-400
0.30
XBD3.2/300-400
0.32
XBD2.8/330-500
330
0.28
1450
160
78
XBD3.0/330-500
0.30
XBD3.2/330-500
0.32
Start, running and stopÂ
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled by water. The pipes shall be sealed, no air leaked. (no-water inside start is forbidden)Â
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check pump impeller, seal ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump.Â
5. When rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen stuff cap. Adjust later when started.
5. In case fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on outlet pipe, close vacuum gauge cock.
2. Stop motor, and close pressure cock.
3. In Winter, drain liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean and lubricate.
TroubleshootingÂ
Â
Fault
Cause
Solution
Pump cannot suck water, pressure gauge & vacuum gauge vibratingÂ
1. Insufficient water pouringÂ
2. Leak between pipe and meterÂ
3. Suction is too high 1, check leak in bottom valve.Â
2, Tighten the leaked partÂ
3, reduce suctionÂ
Pump cannot suck, high vacuum shown in vacuum gauge
1, bottom valve closed or jammedÂ
2, Too great water suction resistanceÂ
3, filter
High Pressure Fire Fighting Water Electric Pump
Model NO.: XBD-(I)
Pump: Booster Pump
Vertical 1-Stage & 1-Priming Pump: Vertical Pump
Electric Pump: Centrifugal Pump
Vertical 1-Stage Pump: Pump
1-Stage & 1-Priming Pump: 1-Priming Pump
Fire Fight Pump: Fire Fight Diesel Pump
Trademark: Borra
Transport Package: Wood Case
Specification: ISO
Origin: Wenzhou
HS Code: 8413810090
Model NO.: XBD-(I)
Pump: Booster Pump
Vertical 1-Stage & 1-Priming Pump: Vertical Pump
Electric Pump: Centrifugal Pump
Vertical 1-Stage Pump: Pump
1-Stage & 1-Priming Pump: 1-Priming Pump
Fire Fight Pump: Fire Fight Diesel Pump
Trademark: Borra
Transport Package: Wood Case
Specification: ISO
Origin: Wenzhou
HS Code: 8413810090
High Pressure Fire Fighting Water Electric Pump